Dyna-Glo RMC-TT30P Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Raumheizungen Dyna-Glo RMC-TT30P herunter. Dyna-Glo RMC-TT30P Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Printed in China
Dyna-Glo
®
Delux Natural
Gas Construction Heater
Operating Instructions & Parts Manual RMC-FA150NGDGD
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
Description
Dyna-Glo Delux model RMC-FA150NGDGD is a natural gas fired construction
heater, having a built-in thermostat, and a 150,000 BTU/Hr rating. The heater
uses natural gas for com bustion and electricity to operate the motor and fan.
It is primarily to be used to temporarily heat well-ventilated buildings under
construction, alteration or repair. This heater should be utilized in sheltered, well-
ventilated areas, but never in occupied dwellings.
Specifications
Figure 1 – Model RMC-FA150NGDGD
Manifold Maximum Supply Minimum Supply Temperature
Model Pressure Pressure to Heater Pressure to Heater Control
RMC-FA150NGDGD 4” W.C. 1/2 PSI 5” W.C. Built-In Thermostat
Spark Plug Ignitor Gap Weight Size
Model Ignition Gap (Inches) (Inches) (Pounds) L x W x H (Inches)
RMC-FA150NGDGD Continuous spark .12 .12 18.6 (Heater) 25 x 9.4 x 15.5
22 (Shipping)
E
N
G
L
I
S
H
E
S
P
A
O
L
F
R
A
N
Ç
A
I
S
PROFESSIONAL GRADE
Table of Contents Page
Description .......................1
Specifications......................1
Unpacking ....................... 1
General Safety Information ........1-3
Principals of Operation..............3
Ventilation........................3
Installation........................4
Operation ........................4
Maintenance ....................4-5
Storage ..........................5
Wiring Diagram....................6
Repair Parts Illustration .............7
Repair Parts List....................7
Troubleshooting Chart ..............8
Warranty .........................9
Unpacking
1. Unpack all materials used to protect
the heater inside of carton. Retain
plastic caps attached to exposed
fittings for use during storage.
2. Remove heater, accessories and all
hardware from carton.
3. Inspect all items for damage that may
have occurred during shipment.
General Safety Information
Make certain you read and understand
all warnings. Keep these instructions for
reference. They are your guide to safe
and proper operation of this heater.
Safety information appears throughout
these instructions. Pay close attention
to them. Below are definitions for the
safety information listed throughout
this manual.
DANGER
Indicates an
im minen tly
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
WARNING
Indicates a poten-
tially hazardous situation which, if not
avoided, COULD result in death or serious
injury.
CAUTION
Indicates a poten-
tially hazardous
situa tion which, if not avoided, MAY
result in minor or moderate injury.
IMPORTANT: Not every possible cir-
cumstance that might involve a hazard
can be anticipated. The warnings in this
manual and on tags or decals affixed to
the unit are therefore not all-inclusive.
If a procedure, work method, or oper-
ating technique not specifically recom-
mend ed by is used, you must make sure
it is safe for you and others.
You should also ensure that equipment
will not be damaged or made unsafe by
the operating or maintenance method
you choose.
Consumer: Retain this manual for future
reference.
Output Rating Fuel Hot Air Output Electric Motor
Model BTU/Hr Fuel Consumption (CFM Approx) Motor Input Amperage
RMC-FA150NGDGD 150,000 Natural Gas Only 146 Cubic Ft/Hr 435 3440 RPM 120V/60Hz, 1/9 HP 0.7
ANS Z83.7-2011 CSA 2.14-2011 Construction Heater
Rev 2013-06-13
US
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - Gas Construction Heater

Printed in ChinaDyna-Glo® Delux Natural Gas Construction HeaterOperating Instructions & Parts Manual RMC-FA150NGDGDPlease read and save these ins

Seite 2 - Construction Heater

WARRANTY REGISTRATIONIMPORTANT: We urge you to fill out your warranty registration card within fourteen (14)days of date of purchase. You can also reg

Seite 3 - Model RMC-FA150NGDGD

General Safety Information (Continued)WARNINGGeneral Hazard Warn ing: Failure to comply with the precautions and instructions provided with this he

Seite 4

General Safety Information (Continued)– This heater is equipped with a thermo-stat. Heater may start at anytime.– Never move, handle, or service a h

Seite 5

InstallationWARNINGReview and under-stand all of the warnings in the Safety Information Section on pages 1–3. They are required to operate this heater

Seite 6

PROFESSIONAL GRADEsection. Repair any leaks immediately.Maintenance (Continued)2. Always keep heater clean. Clean the heater annually, or as often as

Seite 7 - RMC-FA150NGDGD

6Wiring DiagramsDyna-Glo Delux Operating Instructions and Parts ManualDyna-Glo® Delux Natural Gas Construction HeaterRMC-FA150NGDGDFor Technical Suppo

Seite 8

7Dyna-Glo Delux Operating Instructions and Parts ManualRMC-FA150NGDGDFor Repair Parts, call 1-877-447-4768Please provide following information:-Model